600V Kynar/Hmwpe Cathodic Protection Cable
Product Introduction
We mainly deals in Explosion-proof Test Pile, Canistered Cast Iron Anode, SCR Transformer Rectifier, and special specifications products can also be customized according to customer requirements. We provide a large number of products with reliable quality, global availability and expert technical support, so that it occupies a significant competitive advantage in the global market. We will rely on the various experiences accumulated over the years to make the national brand more refined and stronger. We believe that brand inheritance takes product quality as the lifeblood of the company, and we have won the recognition and affirmation of domestic and foreign customers with strength.
Product Introduction
KYNAR/HMWPE cable is used for ac/DC rated voltage up to and including 450/750V control and monitoring circuits and protection circuits.The conductor is allowed to work at 70℃ for a long time, and the maximum working temperature shall not exceed 160℃ in case of short circuit.With good shielding performance, can be used in a variety of environments.It can be widely used in power plants and power stations, and can be laid indoors, in cable trench, pipe, buried, vertical shaft and other occasions with large mechanical tension.
- Product description:
- The cable conductor shall be made of bright soft copper wire with a round or fanny-shaped twisted compacting core. The surface of the conductor shall be smooth, free from oil stains, no damaged insulation burrs, sharp edges, and no raised or broken single wire.
- The maximum rated temperature of the cable conductor during continuous operation shall be 90℃;In case of short circuit (the longest duration shall not exceed 4S), the maximum temperature of the cable conductor shall not exceed 250℃.
- See GB12706 for the nominal insulation thickness of each section, and the average insulation thickness shall not be less than the nominal value.The minimum thickness measured at any point shall not be less than 90% of the nominal value;Eccentricity of any section :(maximum measured thickness - minimum measured thickness)/maximum measured thickness ≤15%.
- The cable core shall be tightly filled with non- hygroscopic soft material, and the cable body shall be round in shape after the cable is made;The degree of roundness should not be more than 15%, and the outer wrapping tape should be used.
- When the cable is armored with galvanized steel tape, the winding shall be smooth and smooth.
Product Parameter
| Technical parameters | |
| Long-term allowable working temperature of cable conductor | -40~+50℃ |
| Monthly average maximum relative humidity | 95%(+25 hours) |
| The permissible temperature for laying and installation of the cable | shall be no less than -10℃ |
| Minimum bending radius of the cable | 10 times the outer diameter of the cable |
Our 600V Kynar/Hmwpe Cathodic Protection Cable enjoys a high reputation because it is constantly improved with our continuous technological innovation. We have now sophisticated machines. We continue to develop new products, improve the grade of original products, and provide excellent after-sales service for each customer while strictly controlling product quality.
Hot Tags: KYNAR HMWPe cable, China, suppliers, manufacturers, factory, cheap, welding junction box, Cement Test Pile, test pile satisfaction, electrochlorination apparatus, chlorination equipment for municipal wastewater treatment, chlorination process for air conditioning condensate treatment