+86-22-59657343
Digital Earth Tester with Measuring The Soil Resistivity and Ground Voltage

Digital Earth Tester with Measuring The Soil Resistivity and Ground Voltage

Soil resistivity tester, also known as the three-wire grounding resistance value tester and the earth resistance meter, is a common instrument for testing and measuring earth resistance.
Send Inquiry
Product Details of Digital Earth Tester with Measuring The Soil Resistivity and Ground Voltage

Product Introduction

At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for Cathodic Protection Welding, ICCP Data Monitoring System, Test Pile. In the rapid development of the industry and our company's continuous and powerful cause, it embodies the burning passion, hard work and innovative wisdom of all our employees. We uphold the business philosophy of 'innovation, quality, efficiency' and the principle of 'customer first' to provide our customers with high-quality professional products and satisfactory integrated services.

Product Introduction

 

  • Product measurement method:

1. Simple grounding resistivity test on two wires

          Second-line test: this method is not to use the simple measuring method of auxiliary grounding rods, using existing minimum grounding resistance of grounding as auxiliary grounding, use two simple test line connection (i.e., G (H) - P (S) interface sub, E - ES interface sub) can use metal hose, fire hydrant metal buried objects, such as commercial common ground of the power system or building lightningproof grounding pole instead of auxiliary grounding rods C (H), P (S), when measuring the attention to remove the selected metal oxide layer of auxiliary grounding body connection point.

 

2. Three-wire test ground resistivity

          Three gauge test: short connected instrument's ES, E interface, namely three-wire test, the instrument operation is the same as four-wire test.Three-wire test cannot eliminate the influence of wire resistance on the measurement, nor can it eliminate the influence of the change of contact resistance between the instrument and the test line or between the test line and the auxiliary ground rod. The oxide layer on the surface of the ground body to be measured should be removed during the measurement.

 

3. Four-wire test ground resistivity

          Four-wire test: Four-wire test can eliminate the influence of contact resistance (usually dirt or rust) between the ground body under test, auxiliary ground rod, test clip and the surface of instrument input interface on measurement, and can eliminate the influence of wire resistance on measurement, which is better than three-wire test.

 

Generally, P(S) and C(H) auxiliary grounding rods are buried deep in the ground in a straight line at an interval of 5m ~ 20m from the object under test. The grounding test wires (black, green, yellow and red) are connected to the grounding pole E, auxiliary voltage pole P(S) and auxiliary current pole C(H) from the interfaces E, ES, P(S) and C(H) of the instrument.

 

  • Precautions for product use:
  1. Choose sunny and dry weather. In case of thunderstorm, stop the test and evacuate the test site.
  2. In the permafrost area, the test electrode is driven below the freezing line.
  3. Where there are underground pipes, the electrodes are arranged in the vertical direction of the pipe, and the distance between the nearest measuring electrode and the underground pipe is required to be no less than the electrode distance.
  4. Select multiple measuring points for stratification measurement.

 

product Parameter

 

Application environment

Ambient temperature

-10℃ ~40℃

Environmental wetness

<80%

Working voltage of the instrument

9v±1.5V

Auxiliary grounding resistance value

< 30kΩ

Interference voltage

<20V

Interference current

<2A

Electrode spacing when Measuring R

a>5d

Electrode spacing when measuring ρ

a> 20h

 

Electrical parameters

Power supply

DC 9V(alkaline dry battery LR14 1.5V 6, continuous standby 300 hours)

Grounding resistance

0. 00 Ω ~ 30.00 kΩ

Soil resistivity

2.3 0. 002 Ω ~ 9000 kΩ

Grounding voltage

0V~600V

Measurement methods

Precise 4-wire, 3-wire measurement and simple 2-wire measurement of ground resistance

Test frequency

128Hz/111Hz/ 105Hz/94Hz (AFC)

Short circuit test current

AC 20mA Max

Open circuit test voltage

AC 40V Max

Test voltage waveform

sine wave

 

Our company can guarantee the quality of our Digital Earth Tester with Measuring The Soil Resistivity and Ground Voltage and services and go abroad with our products and services. We take 'honesty and trustworthiness, seeking truth and being pragmatic' as the market orientation, listening to customer needs, and creating value for customers. Our company advocates maximizing the interests of customers, serving customers in the form of space, and creating the highest corporate return for customers.